更新バージョン
更新年月日
更新内容
Ver.6.08 →
Ver.6.10
2008.09.18
[Added function]
No.1 Support the sequence program and M-EXECUTOR in MP2100/MP2100M (MP2500/MP2500M)
[Added module]
No.2 Support the I/O module (IO2900 and IO2910) for MECHATROLINK
[Added function]
No.3 Renewal the "Motion Editor"
No.4 Renewal the "Drive Control Panel"
No.5 Support the "SigmaWin+" via MP controller
No.6 Support the "Axis setup wizard"
No.7 Support the "XY-Trace"
No.8 Renewal the "Tuning Panel"
No.9 Support the "My Tool"
[Improvement]
No.10 The member name in MSEE structure is renamed
No.11 Update compatible of YMW project file
No.12 Support to one-line comment instruction in motion program
No.13 Transfer all data to controller
No.14 Detection of the PFORK nest error
No.15 Improvement of motion program PFORK-SFORK saving
No.16 Improvement of check processing of the module configuration
No.17 Improvement of M-EXECUTOR definition saving
No.18 Improvement of register range check when module is changed
No.19 Improvement of CNTR-01 print
No.20 Improvement of current step in PFORK at debugging mode
No.21 Improvement of preservation of the SERVOPACK parameter backup file
No.22 Improvement of ladder display update
No.23 Improvement of acquisition of current value of SERVOPACK
No.24 Improvement of motion program saving
No.25 Improvement when motion program single quote is used
Ver.6.07 →
Ver.6.08
2008.05.30
[Added module]
No.1 Support to 263IF-01 module
No.2 Support to IDM servo
No.3 Addition of "Absolute Encoder Reset Completed"
[Added function]
No.4 The MPE720 installer is downloaded from the e-Mechatoronics.com
[Improvement]
No.5 SVA fixed parameter addition
No.6 Change in current value row attribute of I/O module
No.7 SVB monitor parameter addition
No.8 It connects it with the controller immediately after the start of the MPE720
No.9 When the comment is displayed, the most significant comment is displayed
No.10 The branch edits it in the edit mode on the ladder screen
No.11 It two or more deletes it by the Watch sabwindow
No.12 In the watch sabwindow, the operation of drag & drop of the register is changed from "Copy" to "Movement"
No.13 Operation of drag & drop from ladder element instruction
No.14 In the watch sabwindow, the input function of a consecutive address
No.15 In the watch sabwindow, the row order is replaced
No.16 Pop-up menu Addition of watch sabwindow
No.17 The number of maximum registration of member variables of the User structure is changed
No.18 It becomes an error if the MPE720 Ver.6 is started and it doesn't start
No.19 The Import and the Export of the comment on the variable cannot be done
No.20 The display of the tree item remains in each sabwindow when logoffging the MPE720 Ver.6
[Bug fix]
No.21 It is trouble that display of color of register list shifts
No.22 Bug fix of index operation of motion program
[Preventive]
No.23 Spelling error of each parameter
No.24 The unit display of the monitor parameter was corrected
Ver.6.06 →
Ver.6.07
2008.01.24
[Bug fix]
No.1 Bug which using one-byte katakana in the motion program comment
[Preventive]
No.2 Bug of Input/ Output disable operation of I/O message communication
No.3 Spelling error
No.4 Bug of unit of display of SVB linear type for MP2310/ MP2300S/ MP2400
No.5 Bug of the fixed parameter input range
No.6 It is possible to set the size which exceeds the range of the enable allocation of 260IF
Ver.6.05 →
Ver.6.06
2007.11.21
[Added function]
No.1 For Windows Vista
[Added module]
No.2 Support to LIO-06 module
No.3 Support to 262IF-01 module
[Added function]
No.4 Supporting of IO variable (LIO-06/ 262IF-01)
No.5 Export/ import of register data
No.6 Add the index function to motion program
No.7 Add the "default" branch of SFORK instruction
No.8 Easy start of tuning panel
No.9 History of the Start Window can be deleted
No.10 Update the version of MP2100 driver
[Improvement]
No.11 Improvement of project file
No.12 Improvement of transfer rate
No.13 The combo list size for select the motion command was changed
No.14 Improvement of allocation of user structure
No.15 Comparison by off-line of table data
No.16 Occurrence at scan time over
No.17 Improvement of motion program saving error
No.18 Improvement of password change while opened program
No.19 Improvement of program illegal name when transfer
No.20 Improvement of open Adobe Reader version 8 from MPE720 Version 6
No.21 Memory leak in monitor of D register
No.22 Improvement of Conversion from CP Ladder to New Ladder
No.23 Improvement which Choon "ー" is Compiled
No.24 Cut in at the middle of the circuit when ladder program was printed
No.25 Improvement of reflect the setting value in C register by transfer of constant variable
[Preventive]
No.26 Bug of save operation that detailed definition of CNTR-01 module
No.27 Bug of input of hexadecimal number in the motion program
No.28 Bug of block number when ON/OFF is used in the conditional expression
No.29 Width enhancing of grid of motion error list
No.30 Trouble of print
[Bug fix]
No.31 Freezing by printing of the ladder program of 25 parallels of coil
No.32 The current value of all ladders was displayed without shifting
Ver.6.04 →
Ver.6.05
2007.05.23
[Add function]
No.1 SGDV Servo Amplifier selection added to Module Configuration
No.2 Motion parameter addition
No.3 MNET-01 Module addition
No.4 "Phase Reference" command invalidation for MP2400
No.5 Communication Port for MPE720 Lite
No.6 Parameter "Pn000" for "SJDE-**AN*"
[Improvement]
No.7 Group definition of sequence program
No.8 Prohibit duplicated register assignment in the User Structure
No.9 Test Run function for Inverter
No.10 Program can be renamed in the program properties
No.11 Modification of display for CNTR-01 module
[Preventive]
No.12 Eliminate the Error Dialog "CpPnlStatus Error"
No.13 Detailed display in the SERVOPACK parameter screen
No.14 Modification for 218IFA module definition with the non-protocol
No.15 Modification of C-language property
No.16 Modification of Motion Assist function (ASCII)
No.17 Compare function for user structure
Ver.6.03 →
Ver.6.04
2007.03.02
[Add function]
No.1 Controller model (MP2310・MP2300S・MP2400) Addition
No.2 PC-LINK module addition
No.3 AFMP-02-C module addition
No.4 218IF-02 module addition
No.5 Automatic logical port setting to Communication process
No.6 Controller retrieval by 218IF-02
No.7 New motion instruction addition (ASCII/ SSEE/ FUNC/ C-TSK/ C-FUNC)
No.8 For sequence program
No.9 Motion program instruction input support
No.10 Motion program instruction input support (Servo On / Servo Off)
No.11 Motion program instruction input support (Alarm Clear)
No.12 Driving control panel
No.13 Addition of program execution registration screen
No.14 Set parameter addition
No.15 The motion alarm analysis screen is added
No.16 System window addition
No.17 Test run (Servo On (Off) /JOG /STEP /Alarm)
No.18 Axis monitor
No.19 Alarm monitor
[Improvement]
No.20 Compile option setting from environment setting
No.21 Trouble shooting function
[Bug fix]
No.22 Change of name of variable in contradiction to rule
No.23 It makes an error when the MAL file made with Ver.5 is converted with Ver.6
No.24 Trouble that B and W register become unused treatments because of display of map of register list used by ladder application
No.25 When the MAL file made with Ver.5 is converted with Ver.6, the comment on the IO variable is not converted
Ver.6.02 →
Ver.6.03
2006.08.30
[Add module]
No.1 JAPMC-CM2380 (PCLINK-01 Module)
No.2 AFMP-02 (CC-LINK/ANYWIRE Module)
No.3 MPALL00-0, MPAL000-0, MPAN000-0 Module
[Add servo]
No.4 SJDE-**AN*servo addition (JUNMA-MII)
[Add function]
No.5 Motion command addition
- Absolute encoder reset
No.6 Motion parameter addition
- Communication reset (Owxx00: Bit14)
- Gain switch2 (Owxx01: Bit5)
- Latch detection demand completion (Iwxx00: Bit4)
No.7 Correspondence to high-resolution of SVR
No.8 CP Ladder converter
No.9 User structure of variable
No.10 Import and export of variable
No.11 Print manager addition to launcher
No.12 The license agreement on install screen
[Improvement]
No.13 USB Driver update
No.14 Improvement of print function
No.15 Improvement of the arrangement of MECHATROLINK definition
No.16 Improvement of English messages during installation
No.17 Improvement of naming error of the read-only attributed project
No.18 Improvement of the error message due to the screen saver
No.19 Improvement of the print function about [print error]
No.20 Improvement of the print function about the display of unusable function
No.21 Improvement of transfer error which Module configuration file that supported new module
No.22 Improvement the message displayed when close read-only project
No.23 Improvement of ON/OFF control of IME Auto Switching
No.24 Function improvement in branch block
No.25 Improvement of the packet writing function
[Bug fix]
No.26 Modification of the display of auto-complete function of ladder
Ver.6.01 →
Ver.6.02
2006.06.30
[Change specification]
No.1 Change of specification of system work (D register) in Ladder Editor
[Add function]
No.2 Support of C language program
No.3 Add the register jump function of comment list
No.4 Additional function of search/ replace of comment list
No.5 Display the current value/ maximum value of scan time
No.6 Add the function of "save as a new project"
No.7 Import/ Export function of motion parameter
No.8 Function of disagreement data display of current value < - > setting of servopack parameter
No.9 Add C register use enable function in register list
No.10 Add the print function of program call (FUNC/ MSEE) in print manager
No.11 Function of display list of forced coil list
No.12 New support of transfer medium
No.13 Transfer function of comment
No.14 Function of detail compare of ladder program/ motion program
No.15 Add transfer function to Environment Setting
No.16 Variable function: Support of variable to all I/O module
No.17 Automatic creation of axis variable of SVB/ SVA/ PO/ SVR/ MECHATROLINK-II inverter
No.18 Function of trace registration from variable window
No.19 Management of read/ write of comment data
No.20 Communication Process: Extension of the number which simultaneously allocated by the serial port
No.21 Communication Process: Extended COM port number
No.22 Support ****SERVO as MECHATROLINK module
No.23 Communication Process: Support Gateway function
[Bug fix]
No.24 Bug of the error occurring which the Expression instruction of the ladder program
No.25 Bug of the error which restart the project file after shut down
No.26 Bug of the error which register/ variable registered in the watch
No.27 Bug of alarm registration of axis variable alarm
No.28 Bug of the error which save project
No.29 Bug of Undo processing of comment
No.30 Check function of Motion program saving size
No.31 Malfunction of ladder operation when use the register with subscript in the Expression instruction
[Preventive]
No.32 Unusable "Compile to version 5 compatible" before version 5.34
No.33 Bug of the error of "Compile to version 5 compatible"
No.34 Transfer error of servopack parameter of 16th axis
No.35 Bug of transfer at Electronic CamTool
[Improvement]
No.36 Number of drawing of CP ladder program
No.37 Conventional ladder was changed to CP ladder
No.38 Enable to relay connection through MPLINK of 215AIF-01
No.39 Improvement of status of use in register map
No.40 Error in track point central button of IBM ThinkPad
No.41 Change error message in miscompare of FLASH comparison
No.42 Display of confirmation message when all comment list is cleared
No.43 Saving the status of tree/ data format when compiling the watch
No.44 Impossibility of one-byte kana in the logical axis name of group definition
ページトップへ
MPE720 Ver.6へ
コントローラサポートツールへ
e-メカサイト ホームへ
e-メカサイトにご訪問ありがとうございます
ログイン
新規会員登録
会員ID・パスワードを
忘れた方
会員サービスと手続きの
ご案内
サイト内検索
検索ガイド
お客様サポート
ご利用ガイド
ダウンロード
カタログ
マニュアル
外形図/CADデータ
サポートツール
ユーザースクール
トレーニング
eラーニング
Q&A
コントローラQ&A
PLC Q&A
お問い合わせ
技術相談
カタログ・
マニュアルのご請求
お見積もり・ご注文
オンラインショップ
アフターサービス[故障・メンテナンス]
国内拠点
海外拠点
Copyright(C)2001-2008 YASKAWA ELECTRIC CORPORATION. All Rights Reserved.