Specifications

General Specifications
Items Specifications
Environmental Conditions Operating Temperature 0°C to +55°C
Storage Temperature –20°C to +85°C
Operating Humidity 30% to 95% (non-condensing)
Storage Humidity 5% to 95% (non-condensing)
Corrosive Gas No combustible or corrosive gas
Operating Altitude 2,000m above sea level or lower
Electrical Operating Conditions
Noise Resistance Conforming to JIS B3502
Power supply noise (FT noise): 2kV or larger for 1 min.
Radiation noise (FT noise): 2kV or larger for 1 min.
Gland noise (Impulse noise): 1kV or larger for 10 min.
Static noise (Aerial discharge):
8kV or larger for 10 times
Mechanical
Operating
Conditions
Vibration Resistance Conforming to JIS B3502
1)Frequency: 16.7Hz
Vibration acceleration: 14.7m/s2
2 hours in each direction (X, Y, and Z)
2)Frequency: 10Hz to 57Hz
Vibration amplitude: Single-amplitude of 0.075mm
3)Frequency: 57Hz to 150Hz
Vibration acceleration: a fixed acceleration of 9.8m/s2
Shock Resistance Peak acceleration of 294m/s2(30G) twice for 11ms each in directions X, Y, and Z
Installation Requirements Ground Ground to 100Ω or less
Cooling Method Natural cooling

MP2300 Basic Module
Items Specifications
Power Supply Input supply voltage: 24VDC±20%
Current consumption: 1A
Inrush current: 40A or less
Motion Network One circuit for MECHATROLINK-II:
Twenty-one stations, including servo drives and I/O equipment, can be connected. (16 axes for servo drives)
Transmission speed: 10Mbps (MECHATROLINK-II)
Maximum segment length: 50m
I/O Signals Direct input: 8 points (One point can be used for interrupts),
24VDC, 4mA, and source mode or sink mode input
Direct output: 4 points, 24VDC, 100mA, open collector, and sink mode output
Slot for Optional Modules 3 slots